Octave Light R1
Please find below printing settings at 50 micron for PowerResins Burn and PowerResins Opaque resins;
Please note that these settings are provided by customers who are using our resins with Octave Light printers so that may cause discrepancies.
BURN RESIN SETTINGS
| Layer Height |
50 Micron |
| Adjust Resin Depth Speed |
75 um/s |
| Burn-in Exposure Time |
15000 ms |
| Dip Depth |
4000 um |
| Dip Retraction Speed |
17000 um/s |
| Dip Speed |
10000 um/s |
| Exposure Time |
8000 ms |
| Layer Height |
50 um |
| Max Recoater Deviation(steps) |
999999 |
| Max Printable Safety Margin |
1000 um |
| Number of Burn-in Layers |
1 |
| Recoater Extraction Speed |
17000 um/s |
| Recoater Insertion Speed |
17000 um/s |
| Recoating Speed |
1600 step/s |
| Retraction Over Distance |
20 um |
| Wait time Before Exposure |
3000 ms |
|
OPAQUE RESIN SETTINGS
| Layer Height |
50 Micron |
| Adjust Resin Depth Speed |
75 um/s |
| Burn-in Exposure Time |
15000 ms |
| Dip Depth |
4000 um |
| Dip Retraction Speed |
17000 um/s |
| Dip Speed |
10000 um/s |
| Exposure Time |
8000 ms |
| Layer Height |
50 um |
| Max Recoater Deviation(steps) |
999999 |
| Max Printable Safety Margin |
1000 um |
| Number of Burn-in Layers |
1 |
| Recoater Extraction Speed |
17000 um/s |
| Recoater Insertion Speed |
17000 um/s |
| Recoating Speed |
1600 step/s |
| Retraction Over Distance |
20 um |
| Wait time Before Exposure |
3000 ms |
|